Integrity Testing with Pull-out Anchor Testers

Designed for versatility and ease of use, our testers provide comprehensive solutions for evaluating the performance of anchors in various construction applications.

Introducing Our Pull-out Anchor Testers

Our Pull-out Anchor Tester Products

Notebook

Notebook

Capture structured and unstructured lab work with the first cloud-based notebook built for biotech.
Learn more
Studies

Studies

Efficiently oversee in vivo studies using modern software specifically designed for data collection, collaboration, and analysis.
Learn more
Inventory

Inventory

Outgrid sample management solution gives you lab inventory management that’s intelligently connected with your R&D data.
Learn more
Insights

Insights

Create and distribute dashboards and reports, monitor metrics, and gain insights from your data with Insights.
Learn more

Applications of Pull-out Anchor Testers

Product Comparison

Discover the ideal Anchor Tester for your construction projects with our detailed product comparison. Assess accuracy, reliability, and ease of use to ensure secure and dependable anchoring solutions.
Model
LR-10T/20T/30T Anchor Bolt Pull Out Tester
LR-50T/100T Anchor Bolt Pull Out Tester
LR-M1/M2/M3/M4/M5 Anchor Bolt Pull Out Tester

Cylinder center hole

LR-10T: 27mm
LR-20T: 35mm
LR-30T: 45mm
LR-50T: 60mm
LR-100T: 86mm

LR-M1: 18mm
LR-M2: 18mm
LR-M3: 18mm
LR-M4: 18mm
LR-M5: 18mm

Cylinder stroke

LR-10T: 60mm
LR-20T: 70mm
LR-30T: 70mm

LR-50T: 120mm
LR-100T:150mm

LR-M1: 50mm
LR-M2: 50mm
LR-M3: 50mm
LR-M4: 50mm
LR-M5: 50mm

Measurement range

LR-10T: 0-100kN
LR-20T: 0-200kN
LR-30T: 0-300kN
LR-50T: 0-500kN
LR-100T: 0-1000kN
LR-M1: 0-10kN
LR-M2: 0-20kN
LR-M3: 0-30kN
LR-M4: 0-40kN
LR-M5: 0-50kN

Cylinder weight 

LR-10T: 5.5kg
LR-20T: 13kg
LR-30T: 15kg
LR-50T: 25kg
LR-100T: 58kg
LR-M1: 1.5kg
LR-M2: 1.5kg
LR-M3: 1.5kg
LR-M4: 1.5kg
LR-M5: 1.5kg

Common anchorage

LR-10T: Φ6-Φ20
LR-20T: Φ6-Φ25
LR-30T: Φ6-Φ32
LR-50T: Φ6-Φ40
LR-100T: Φ25-Φ50
LR-M1: Φ6-Φ12
LR-M2: Φ6-Φ12
LR-M3: Φ6-Φ12
LR-M4: Φ6-Φ12
LR-M5: Φ6-Φ12

Pull rod

LR-10T: M18
LR-20T: M24
LR-30T: M30
LR-50T: M39
LR-100T: M45
LR-M1: M12
LR-M2: M12
LR-M3: M12
LR-M4: M12
LR-M5: M12

Converter

LR-10T: M6-20
LR-20T: M6-22
LR-30T: M6-27
LR-50T: M6-36
LR-100T: M20-42
LR-M1: M6-10
LR-M2: M6-10
LR-M3: M6-10
LR-M4: M6-10
LR-M5: M6-10
Model
Cylinder center hole
Cylinder stroke
Measurement range
Cylinder weight
Common anchorage
Pull rod
Converter

LR-10T

27mm

60mm

0-100kN

5.5kg

Φ6-Φ20

M18

M6-20

LR-20T

35mm

70mm

0-200kN
13kg
Φ6-Φ25
M24
M6-22
LR-30T
45mm

70mm

0-300kN
15kg
Φ6-Φ32
M30

M6-27

LR-50T
60mm
120mm
0-500kN
25kg
Φ6-Φ40
M39
M6-36
LR-100T
86mm
150mm
0-1000kN
58kg
Φ25-Φ50
M45
M20-42
LR-M1
18mm
50mm
0-10kN
1.5kg
Φ6-Φ12
M12
M6-10
LR-M2
18mm
50mm
0-20kN
1.5kg
Φ6-Φ12
M12
M6-10
LR-M3
18mm
50mm
0-30kN
1.5kg
Φ6-Φ12
M12
M6-10
LR-M4
18mm
50mm
0-40kN
1.5kg
Φ6-Φ12
M12
M6-10
LR-M5
18mm
50mm
0-50kN
1.5kg
Φ6-Φ12
M12
M6-10

Enhance Your Anchoring Solutions Today!

Experience the precision and reliability of Langry’s Pull-out Anchor Testers for yourself.

OEM/ODM Capabilities of Langry NDT

Go beyond the ordinary with LANGRY’s comprehensive OEM and ODM services for NDT Equipment. We empower you to customize every aspect of our products, from the inside out.
  • Integrate your logo seamlessly onto the front-of-box label, nameplate, and user manual. Simply send us your logo file, and we'll handle the rest.

  • Ensure everything meets your expectations. We'll send you a sample rebound hammer customized with your branding for approval before production begins.

Contact LANGRY today to explore the possibilities and receive a personalized quote. We’re here to turn your vision into a reality.

Frequently Asked Questions

What types of anchoring components can be tested with LANGRY's pull-out anchor testers?
LANGRY’s pull-out anchor testers are suitable for testing various anchors, rebars, expansion bolts, and other anchoring components, providing accurate assessments of anchoring force and tensile strength.
What materials are LANGRY's pull-out anchor testers made of?
Our pull-out anchor testers feature a main body of thicker high-strength steel, ensuring durability and stability under high pressure. Precision machining technology is used to maintain constant pressure and prevent oil leakage during testing.
What user-friendly features are included in LANGRY's pull-out anchor testers?
LANGRY’s pull-out anchor testers come equipped with a range of user-friendly features, including a memory capacity of 500 data records, a dot-matrix LCD with backlighting, zero tracking, peak hold, automatic shutdown, and automatic broken line correction for improved accuracy.
How long is the working time of LANGRY's pull-out anchor testers?
Our pull-out anchor testers feature an ultra power-saving design that ensures extended working time of more than 200 hours, making them ideal for long-term use in the field.
Please enable JavaScript in your browser to complete this form.
Name

Frequently Asked Questions

What is a Testing Anvil Calibration Tool?

A Testing Anvil Calibration Tool is a precision instrument used to calibrate rebound hammers, ensuring accurate and consistent testing results in various applications such as construction, geotechnical engineering, and materials testing.

How does a Testing Anvil Calibration Tool work?
The Testing Anvil Calibration Tool is placed on a rigid horizontal surface, and the rebound hammer is used to conduct vertical or horizontal rebound tests on its surface. The calibration value of the rebound hammer is then adjusted based on the results obtained from the anvil.
Why is calibration important for rebound hammers?
Calibration is essential to ensure the accuracy and reliability of rebound hammers in assessing the compressive strength of concrete and other materials. Proper calibration guarantees consistent and trustworthy testing results, vital for quality control and safety in construction and materials testing.
How often should a Testing Anvil Calibration Tool be replaced?
The lifespan of a Testing Anvil Calibration Tool depends on factors such as usage frequency and maintenance practices. Generally, these tools are durable and can be used for an extended period. However, it is recommended to monitor the condition of the anvil core and body and replace them if signs of wear or damage are observed to maintain calibration accuracy.
Please enable JavaScript in your browser to complete this form.
Name

Gather, systematize, and consolidate R&D information.

Facilitate collaboration and knowledge-sharing among R&D teams.

Give scientists, managers, and executives the answers they need

Operational insights

Operational insights

Dive deeper into resource allocations, processes, and usage to enhance program management, gauge team productivity, and optimize workflows.
Administrative insights

Administrative insights

Get a real-time understanding of how Benchling is being used across resources, programs, and teams, and actively understand the level of compliance.
Scientific insights

Scientific insights

Analyze data to understand and compare results within, or across, experiments. Leverage these insights to make more informed decisions critical to R&D pipeline.

Suitable solutions for your research needs

The current age of scientific advancement has resulted in a proliferation of novel innovations in various domains such as cellular therapy, genetic therapy, antibodies, proteins, and other emerging drug methodologies.
Biopharmaceutical

Biopharmaceutical

Find new leads faster, develop promising candidates more effectively, and create innovative therapies through collaboration…
Learn more
Agritech R&D

Agritech R&D

Create new plant varieties and characteristics, innovate in the field of agriculture technology, and record experiments and fieldwork…
Learn more
Industrial Biotech R&D

Industrial Biotech R&D

Develop genetic sequences and strains, expand development procedures, and oversee sample traceability—all through a cohesive…
Learn more
Bioprocess development

Bioprocess development

Established workflows for the development of biologics, based on the most effective practices in the industry, and implemented on….
Learn more